Swift XRT Combined Intensity Images

The Swift XRT (Burrows et al 2005, SSRv, 120, 165) is a sensitive, broad-band (0.2 - 10 keV) X-ray imager with an effective area of about 125 cm**2 at 1.5 keV. The 600 x 600 pixel CCD at the focus provides a 23.6' x 23.6' field of view with a pixel scale of 2.36". The point spread function
is 18" (HPD) at 1.5 keV.

These XRT surveys represent the data from the first 12.5 years of Swift X-ray observations. They include all data taken in photon counting mode. A total of just over 8% of the sky has some non-zero exposure. The fraction of sky exposed as a function of the exposure is given in the following table:

Exposure>0 10 30 100 300 1000 3000 1000 30000 100000300000 Coverage 8.42 8.37 8.29 7.67 7.29 5.68 3.40 1.26 0.35 0.044 0.00118

The individual exposure and counts maps have been combined into a Hierarchical Progressive Survey (HiPS) where the data are stored in tiles in the HEALPix projection at a number of different resulutions. The highest resolution pixels (HEALPix order 17) have a size of roughly 1.6". Data are also stored at lower resolutions at factors of 1/2, 1/4, 1/8, 1/16, and 1/32, and in an all sky image with a resolution 1/256 of the higest resolution. An intensity map has been created as the ratio of the counts and exposure maps.

These surveys combine the basic count and exposure maps provided as standard products in the Swift XRT archive in obsid/xrt/products/*xpc_(sk|ex).img.gz. The surveys were created as follows:

All of the exposure maps available in the archive in mid-May 2017 were combined using the CDS-developed Hipsgen tool. This includes 129,063 observations for which both count and exposure files were found in PC mode. Three exposures where there was a counts map but no exposure map were ignored. A few exposure files had more than one exposure extension. 1,082 files had two extensions and 1 file had 3 extensions. The 1084 HDUs in extensions were extracted as separate files and included in the total exposure. The value of 0 was given to the Hipsgen software as the null value for the FITS files. This caused the CDS software to treat such pixels as missing rather than 0 exposure.

The counts data was extracted from the counts maps for each observation using SkyView developed software. For any pixel in which a count was recorded, the corresponding exposure file was checked and if there was any exposure (in any of the associated extensions), then the count was retained. If there was no exposure in any of the extensions of the corresponding exposure file, the counts in the pixel were omitted. Once a count was accepted, the overlap between the counts map pixel and the pixels of the corresponding HiPS tile (or tiles) was computed. Each count was then assigned entirely to a single pixel in the HiPS tile randomly but with the destination pixel probabilities weighted by area of the overlap. Thus if several pixels were found in a given counts map pixel they might be assigned to different pixels in the output image. The HiPS pixels (~1.6") used were of substantially higher resolution than the XRT resolution of 18" and somewhat higher than the counts map resolution of 2.36".

A total of 183,750,428 photons were extracted from the counts maps while 15,226 were rejected as being from pixels with 0 exposure. There were 501 pixels which required special treatment as straddling the boundaries of the HEALPix projection.

The resulting counts tiles were then clipped using the exposure tiles that had been previously generated. Basically this transferred the coverage of the exposure tiles to the counts tiles. Any counts pixel where the corresponding exposure pixel was a NaN was changed to a NaN to indicate that there was no coverage in this region.

During the clipping process 137,730 HiPS level 8 were clipped (of 786,432 over the entire sky). There were 12,236 tiles for which there was some exposure but no counts found. During the clipping process 2 photons were found on pixels where there was no corresponding exposure in the exposure tiles. This can happen when the pixel assignment process noted above shifts a photon just outside the exposed region but should be -- as it was -- rare. These photons were deleted.

After creating the clipped level 8 counts maps, level 7 to 3 tiles and an all sky map where generated by averaging pixels 2x2 to decrease each level. When adding the four pixels in the level N map together only pixels whose value was not NaN were considered.

Finally an intensity map was created by dividing the counts tiles by the exposure tiles. To eliminate gross fluctuations due to rare counts in regions with very low exposure, only regions with exposure > 1 second were retained. A total of 30 photons were deleted due to this criterion.

Note that while any sampler may in principle be used with these data, the Spline sampler may give unexpected results. The spline computation propogates NaNs thought the image and means that even occasional NaNs can corrupt the output image completely. NaNs are very common in this dataset.
Also, if the region straddles a boundary in the HEALPix projection, the size of the requested input region is likely to exceed memory limits since the HiPS data are considered a single very large image. Provenance: Data generated from public images at HEASARC archive. This is a service of NASA HEASARC.

Identifier
Source https://dc.g-vo.org/rr/q/lp/custom/nasa.heasarc/skyview/swiftxrt
Related Identifier https://skyview.gsfc.nasa.gov
Related Identifier https://skyview.gsfc.nasa.gov/cgi-bin/query.pl
Metadata Access http://dc.g-vo.org/rr/q/pmh/pubreg.xml?verb=GetRecord&metadataPrefix=oai_b2find&identifier=ivo://nasa.heasarc/skyview/swiftxrt
Provenance
Creator Data generated from public images at HEASARC archive
Publisher NASA/GSFC HEASARC
Contributor Skyview Project
Publication Year 2024
OpenAccess true
Contact SkyView Help <Skyview at skyview.gsfc.nasa.gov>
Representation
Resource Type Dataset; AstroObjects
Discipline Astrophysics and Astronomy; Natural Sciences; Observational Astronomy; Physics