Here, we present the first application of the temperature sensor module (TSM) for detecting groundwater flow velocity and direction. The TSM maps the horizontal temperature distribution around a borehole heat exchanger (BHE). Groundwater flow distorts this temperature distribution. Thus, flow velocity and direction can be inferred from the measured temperatures.As modular systems, TSMs can be attached to BHE at any depth of interest. For the studied BHE, the depths of interest are at 82 m and 94 m, where we installed TSMs. We recorded TSM data for two weeks before and during the operation of the BHE. After simulating the working fluid temperature in the depths of interest, we model the horizontal temperature distributions using the working fluid temperatures as input. By minimizing the root mean square error between the measured and simulated temperatures, we obtain groundwater flow of (0.4 ± 0.1) m per day in NW direction in 82 m depth and no-flow or flow below the detection limit (0.01 m to 0.02 m per day according to the temperature difference between inlet tubes and outlet tubes ) in 94 m depth, respectively. The results agree within the error bounds with the groundwater flow obtained by an optical method.
Project: Exergetic optimal operation of a multifunctional building involving a geothermal borehole heat exchanger (BHE) field, under grant FKZ 03ET1022AHere are the data for the first TSM module in 82 m depth. The data show the measured temperatures for the sensors of the outer rings. Every 8 sensors belong to one ring in one level. Hence 3 levels each with 8 sensors are given.