Time series (2018) of irradiance in the PAR (photosynthetically active radiation) region measured under the dome of a light observatory in the Arctic (Ny-Ålesund, Svalbard, Norway) derived from an USSIMO spectroradiometer

DOI

UiT The Arctic University of Norway (UiT) and the Norwegian University of Science and Technology (NTNU) established a light observatory at Kings Bay, Ny-Ålesund (Svalbard, Norway) in January 2017. The observatory consists of an array of light sensors including an all sky camera. It is located outside the settlement of Ny-Ålesund, approximately 1 km N-NW of the airport towards Brandalspynten. The array of sensors is mounted on a tripod under a transparent dome. This dataset contains the data of the hyperspectral radiometer USSIMO (In-situ Marine Optics, Perth, WA, Australia), converted to E(PAR) by the following equation: PAR is approximated as an integral of micromolespersec=(uirr/(hc/(lambda1e-9)))/microavo for wavelengths(lambda) in range from 400 to 700nm, where: uirr = USSIMO irradiance for wavelength equal to lambda, h=6.63e-34 [Js], c=3.00e+08 [m/s], microavo=6.022e17. The sensor is equipped with a Zeiss MMS1 UV-VIS NIR detector with National Institute of Standards and Technology, USA traceable radiometric calibration between 380 and 900 nm. This instrument is used for time-series measurement of down-welling spectral irradiance in energy Wm-2 nm-1. Spectral resolution is 10 nm (3.3 nm pixel spacing) and a cosine-corrected polytetrafluoroethylene (PTFE) light diffusor with cosine error: <3% (0 - 60°), <10% (60 - 87.5°), is fitted. The device acquired measurements with a 16 bit analogue to digital converter. It samples continuously internally. Integration time is controlled by the sensor depending on the light intensity, with a maximum of 6 seconds. Actual integration time is stored with the data in each sample. The sensor output is saved on a PC with custom software which records 30 seconds of output data every 29:30 min. The number of samples collected in that period depends on the USSIMO integration time. The sensor is equipped with a pitch and roll sensor which is used to ensure that the spectroradiometer remains in the fixed position throughout the time-series acquisition. For re-use of the data, please refer to the dataset and the original publication.  This is the 2018 dataset. There is larger gap from 2018-10-28 09:00 to 2018-11-05 10:00 due to sensor failure.

Identifier
DOI https://doi.org/10.11582/2021.00041
Metadata Access https://search-api.web.sigma2.no/norstore-archive/oai/v1.0?verb=GetRecord&metadataPrefix=oai_dc&identifier=doi:10.11582/2021.00041
Provenance
Creator Berge, Jørgen; Grant, Stephen; Bjørgum, Rune; Cohen, Jonathan H.; McKee, David; Johnsen, Geir; Zolich, Artur; Kopec, Tomasz Piotr; Vogedes, Daniel Ludwig; UiT The Arctic University of Norway, UiT
Publisher Norstore Archive
Publication Year 2021
OpenAccess true
Contact Norstore Archive
Representation
Language English
Resource Type Dataset
Discipline Natural Sciences; Physics