Concentration (1 file), daily load (1 file) and population normalized daily load (1 file) for a group of pharmaceutical emmited to sewage water in six sewage treatment plants in different Spanish cities. The data corresponding to these cities and their sewage treatment plant is detailed in a separated file (calculation parameters).
PNDL: Population normalized daily load
Estimated population served by the WWTP
Madrid 1:352188
Madrid 2:727176
Tarragona:115567
Reus:108953
Palma de Mallorca:472319
Las Palmas de Gran Canarai:477857
Madrid1 Madrid2 Tarragona Reus Palma Las Palmas GC
Flow (m3/day) - Tu 74324 66182 25387 17672 65222 39533
Flow (m3/day) - W 73508 64454 24513 17380 71576 38759
Flow (m3/day) - Th 71684 63590 24499 16912 65484 37920
Flow (m3/day) - Fr 73324 63418 25919 18512 65664 34472
Flow (m3/day) - Sa 69420 61344 24038 20476 62660 33804
Flow (m3/day) - Su 79208 61344 24205 16152 61909 37567
Flow (m3/day) - Mo 84248 63418 24269 15628 66249 37495
Average 75102 63393 24690 17533 65538 37079
LOQ : limit of quantification