Table 4: Directly-measured friction velocity dependence
MS = Megasplay, Dec = Decollement.Japan Trench data from from Ikari et al. (2015). -
Table 3: Input parameters to model velocity-dependent friction parameters
Japan Trench data from Ikari et al. (2015). -
Table 2: Model-extracted velocity-dependent friction parameters
Japan Trench data from Ikari et al. (2015). -
Laboratory friction experiments on natural samples from IODP Expedition 316 a...
This dataset has no description
-
Shear strength rates and slip measurements from IODP Expedition 316 and ODP H...
This dataset has no description
-
(Table 2) Experimental testing and best-fit curve measurements on unsheared s...
This dataset has no description
-
(Table 1) Permeability measurements on sheared samples from different IODP Ho...
This dataset has no description
-
Version 2 - Friction velocity dependence of sediments from the Nankai Trough,...
To investigate frictional behavior of sediments along the Kumano transect in the Nankai Trough, Japan, friction experiments were conducted using a single-direct shear device at... -
Friction velocity dependence of sediments from the Nankai Trough, Japan
To investigate frictional behavior of sediments along the Kumano transect in the Nankai Trough, Japan, friction experiments were conducted using a single-direct shear device at... -
(Table 1) Experimental shear strength values for IODP Exp315 and Exp316 holes
We investigate the mechanics of slope failures on the Nankai accretionary complex offshore Japan in the vicinity of a major out-of-sequence thrust fault (termed the... -
Dipicolinic acid concentration in sediment samples
Marine sediments host an unexpectedly large microbial biosphere, suggesting unique microbial mechanisms for surviving burial and slow metabolic turnover. Although dormancy is... -
Table 5: Laboratory SSE measurements
Japan Trench data from Ikari et al. (2015). -
MSCL measurements from IODP Hole 316-C0007C
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0008C
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0008B
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0008A
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0007D
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0007B
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0007A
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit. -
MSCL measurements from IODP Hole 316-C0006F
Update on 2018-01-19: Parameter 'Susceptibility, volume' has been converted from [10-5 SI] to [10-6 SI]. All values were previously given in the wrong unit.