-
Mesozooplankton average mass during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton average length during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton abundance during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton biomass during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton average mass during Professor Vodyanitskiy cruise PV13, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML24, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML15, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML14, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Vernadsky cruise AV9, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV13, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton average length during Mikhail Lomonosov cruise ML24, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Mikhail Lomonosov cruise ML15, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Mikhail Lomonosov cruise ML14, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Akademik Vernadsky cruise AV9, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton adundance during Professor Vodyanitskiy cruise PV13, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh sizes of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton adundance during Mikhail Lomonosov cruise ML30, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton adundance during Mikhail Lomonosov cruise ML25, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton adundance during Mikhail Lomonosov cruise ML24, Part I
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system...