-
Concentrations of total organic carbon in waters of the Baltic Sea at Station...
Not filtered water samples were taken in 10 ml ampoules (sealed immediately after being acidified with phosphoric acid to pH<2, sampling), or 40 ml screw-lid vials, and... -
Concentrations of total organic carbon in waters of the Baltic Sea at Station...
Not filtered water samples were taken in 10 ml ampoules (sealed immediately after being acidified with phosphoric acid to pH<2, sampling), or 40 ml screw-lid vials, and... -
Concentrations of total organic carbon in waters of the Baltic Sea at Station...
Not filtered water samples were taken in 10 ml ampoules (sealed immediately after being acidified with phosphoric acid to pH<2, sampling), or 40 ml screw-lid vials, and... -
Particulate organic carbon and nitrogen at bottle station SEPT-1999-K7
POC/PON measured on a EA 1108 CHN Fisons Instruments CHN analyser according to the methodology suggested by Cutter, G.A. & J. Radford-Knoery (1991) and Verardo et al (1990). -
Particulate organic carbon and nitrogen at bottle station SEPT-1999-K5
POC/PON measured on a EA 1108 CHN Fisons Instruments CHN analyser according to the methodology suggested by Cutter, G.A. & J. Radford-Knoery (1991) and Verardo et al (1990). -
Particulate organic carbon and nitrogen at bottle station SEPT-1999-K3
POC/PON measured on a EA 1108 CHN Fisons Instruments CHN analyser according to the methodology suggested by Cutter, G.A. & J. Radford-Knoery (1991) and Verardo et al (1990). -
Primary production of carbon from three subfractions at bottle station SEPT-1...
Photosynthetic productivity was measured according to the in situ 14C method. Fractionation was carried out by filtration through polycarbonate Millipore filters having... -
Primary production of carbon from three subfractions at bottle station SEPT-1...
Photosynthetic productivity was measured according to the in situ 14C method. Fractionation was carried out by filtration through polycarbonate Millipore filters having... -
Primary production of carbon from three subfractions at bottle station SEPT-1...
Photosynthetic productivity was measured according to the in situ 14C method. Fractionation was carried out by filtration through polycarbonate Millipore filters having... -
Chlorophyll concentration in three subfractions at bottle station SEPT-1999-K7
Separate filtration through polycarbonate Millipore filters having porosities 0.2 (total stock), 1.2 and 3.0µm. -
Chlorophyll concentration in three subfractions at bottle station SEPT-1999-K5
Separate filtration through polycarbonate Millipore filters having porosities 0.2 (total stock), 1.2 and 3.0µm. -
Chlorophyll concentration in three subfractions at bottle station SEPT-1999-K3
Separate filtration through polycarbonate Millipore filters having porosities 0.2 (total stock), 1.2 and 3.0µm. -
Microplankton abundance at bottle station SEPT-1999-K7
Microplankton species composition analysis was performed according to the Utermöhl (1958) inverted microscope method. Samples for the identification and enumeration of larger... -
Microplankton abundance at bottle station SEPT-1999-K5
Microplankton species composition analysis was performed according to the Utermöhl (1958) inverted microscope method. Samples for the identification and enumeration of larger... -
Microplankton abundance at bottle station SEPT-1999-K3
Microplankton species composition analysis was performed according to the Utermöhl (1958) inverted microscope method. Samples for the identification and enumeration of larger... -
Nutrients from bottle profile SEPT-1999-K7
This dataset has no description
-
Nutrients from bottle profile SEPT-1999-K5
This dataset has no description
-
Nutrients from bottle profile SEPT-1999-K3
This dataset has no description
-
Total organic carbon from bottle APRIL-2000-K6
The samples (10 ml) were obtained in pre-combusted (480oC, 12 h) glass ampoules, acidified with HCl to 0.1% by volume and flame - sealed immediately on board. High Temperature... -
Total organic carbon from bottle APRIL-2000-K4
The samples (10 ml) were obtained in pre-combusted (480oC, 12 h) glass ampoules, acidified with HCl to 0.1% by volume and flame - sealed immediately on board. High Temperature...