-
Mesozooplankton average length during Professor Vodyanitskiy cruise PV23
Mesozooplankon was sampled in drifting and daily stations using JOM (Juday net, Ocean Model) net with 0.5 m**2 mouth diameter and mesh size 145 µm. Depth of tow is evaluated by... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV14
Mesozooplankton was sampled by open-closing JUDAY net with a 37 cm ring diameter (0.1 m**2 mouth area) and mesh sizes of 125 µm. Depth of tow is evaluated by wire paid out and... -
Mesozooplankton average mass during Professor Vodyanitskiy cruise PV23
Mesozooplankon was sampled in drifting and daily stations using JOM (Juday net, Ocean Model) net with 0.5 m**2 mouth diameter and mesh size 145 µm. Depth of tow is evaluated by... -
Mesozooplankton average mass during Professor Vodyanitskiy cruise PV20, Part II
Mesozooplankton was sampled by JUDAY net with a 37 cm ring diameter and mesh sizes of 125 µm. Integrated hauls (0-200 m) were usually taken. Depth of tow was evaluated by wire... -
Mesozooplankton average mass during Professor Vodyanitskiy cruise PV18, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Professor Vodyanitskiy cruise PV13, Part V
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML30, Part V
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. Additionally, the JUDAY oceanic model JOM with 300 µm mesh size and 80... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML15, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML14, Part V
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Mikhail Lomonosov cruise ML13, Part III
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Vernadsky cruise AV3, Part IV
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.125 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Kovalevsky cruise AK7/5, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.145 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Kovalevsky cruise AK7/3, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.145 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Kovalevsky cruise AK7/2, Part IV
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.145 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average mass during Akademik Kovalevsky cruise AK7/1, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.145 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Akademik Kovalevsky cruise AK7/2, Part II
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 0.145 mm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV21, Par...
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV20, Par...
Mesozooplankton was sampled by JUDAY net with a 37 cm ring diameter and mesh sizes of 125 µm. Integrated hauls (0-200 m) were usually taken. Depth of tow was evaluated by wire... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV18, Par...
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system... -
Mesozooplankton average length during Professor Vodyanitskiy cruise PV13, Part V
Mesozooplankton was sampled by open-closing JUDAY net with a 36 cm ring diameter and mesh size of 125 µm. The open-closing mechanism used was the Nansen mechanical lock system...
