-
X-Ray Fluorescence and Visible Spectroscopy Data from Berlin, Staatsbibliothe...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 15s each), and Visible spectroscopy (SPM100, Gretag-Imaging AG: 380 nm to 730 nm) analysis of ink and pigments... -
X-Ray Fluorescence Data from Diözesan- und Dombibliothek Köln Mss. Cod. 12 an...
XRF (Bruker Artax: 50kV, 600 µA, line measurements of 10 spots of 30s each) analysis of ink and pigments from Diözesan- und Dombibliothek Köln Mss. Cod. 12 (ca.... -
X-Ray Fluorescence, Reflectography and Fourier-transform Infrared Spectroscop...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points, diverse times used (12 to 30s), & spot analyses of 120s), Reflectography (DinoLite: x50 magnification, vis, NIR and... -
X-Ray Fluorescence and Reflectography Data from Hamburg, Staats- und Universi...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 to 26 points of 20s each) and reflectography (DinoLite: x50 magnification under vis, NIR and UV light) analysis of manuscripts... -
X-Ray Fluorescence and Relectography Data from Paris, Bibliothèque Nationale ...
XRF (Elio: 40kV, 20 µA, spot measurements of 60s each), and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from BNF Lat9654 from the... -
X-Ray Fluorescence Data from Karlsruhe, Badische Landesbibliothek, Ms Aug. Pe...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 30s each) analysis of inks from Ms Aug. Perg. 112 from the Badische Landesbibliothek, Karlsruhe (Germany). Analysis of... -
X-Ray Fluorescence Data from Fulda, Hochschul- und Landesbibliothek Fulda, Ms...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 30s each) analysis of inks from Mss AA2 and D1 from the Hochschul- und Landesbibliothek Fulda (Germany). Analysis of... -
X-Ray Fluorescence and Reflectography Data from Munich, Staatsarchiv München ...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Staatsarchiv... -
X-Ray Fluorescence Data from Dublin (Ireland), Chester Beatty Library, Ms Cod...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) analysis of inks from Ms Pma5 / Medinet Madi Codex B (late 4th -5th century CE) from Dublin Chester Beatty... -
X-Ray Fluorescence and Reflectography Data from Cambridge, Wren Library Ms B1...
XRF (Elio: 40kV, 100 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, x200 magnification for spots on... -
X-Ray Fluorescence Data from Copenhagen,Royal Library, Ms GKS1810
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 15s each) analysis of ink on Ms GKS1810 (13th century CE) from the Royal Library, Copenhagen as part of SFB950 project... -
X-Ray Fluorescence and Reflectography Data from Wolfenbüttel, Herzog August B...
XRF (ARTAX: 50kV, 600 µA, linescans of 10 points of 30s each) and reflectography (DinoLite: x50 magnification under vis, NIR and UV light) analysis of inks and pigments... -
Deutscher Orientalistentag 2022 presentation: Same but different – XRF study ...
Same but different – XRF study of inks from 13-14th centuries Torah scroll Ms Erfurt 7 (Berlin, Staatsbibliothek Preussicher Kulturbesitz, Ms. Or. fol. 1216) is a... -
X-Ray Fluorescence and Reflectography Data from Milan, Ambrosian Library, Ms ...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks from Milan, Ambrosian... -
X-Ray Fluorescence and Reflectography Data from Berlin, Staatsbibliothek zu B...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
X-Ray Fluorescence and Reflectography Data from Forschungsbibliothek Gotha Ms...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
X-Ray Fluorescence and Reflectography Data from Dublin, Chester Beatty Librar...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification, vis, NIR and UV light) analysis of inks and pigments (for... -
Multispectral Imaging Data of the Fragment Collection B 7 ("Welscher Gast") o...
Multispectral imaging data of selected areas of the fragment collection B 7 owned by Universitätsbibliothek Erlangen-Nürnberg. The multispectral images were... -
X-Ray Fluorescence and Reflectography Data from Berlin, Staatsbibliothek zu B...
XRF (Elio: 40kV, 80 µA, spot measurements of 120s each) and reflectography (DinoLite: x50 magnification for spots on ink and pigment, vis, NIR and UV light) analysis... -
Measurements of imprints of spectacle frames in the Campione dei Beni, 1504 (...
This dataset was created in the context of the publication A. Janke, C. Colini, K.A. Huskin, S. Bosch, and I. Shevchuk, "A Second Look at Multispectral Data of Late...