-
X-ray diffraction results from IODP Hole 357-M0072B
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. -
X-ray diffraction results from IODP Hole 357-M0071C
= poor data quality. Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized... -
X-ray diffraction results from IODP Hole 357-M0071B
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. -
X-ray diffraction results from IODP Hole 357-M0071A
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. -
X-ray diffraction results from IODP Hole 357-M0070C
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. Other poorly... -
X-ray diffraction results from IODP Hole 357-M0069A
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. -
X-ray diffraction results from IODP Hole 357-M0068B
= poor data quality, ** = duplicate sample. Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or... -
X-ray diffraction results from IODP Hole 357-M0068A
Percentages were released by the software, sometimes with excess. Total sum <100% likely reflects the presence of amorphous or poorly crystallized material. -
Sensor signal time log from IODP Hole 357-M0075B
This dataset has no description
-
Sensor signal time log from IODP Hole 357-M0075A
This dataset has no description
-
Sensor signal time log from IODP Hole 357-M0068B
This dataset has no description
-
Sensor signal time log from IODP Hole 357-M0068A
This dataset has no description
-
Concentrations of anions in fluid samples from IODP Hole 357-M0076B
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0075X
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0075B
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0075A
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0074A
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0073A
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0072Z
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection. -
Concentrations of anions in fluid samples from IODP Hole 357-M0072X
Sample precisions were ±3.9% for Cl, ±2.2% for Br, and ±4.3% for SO4, whereas both NO3 and F were at the limit of detection.
