-
Aerosol size distribution between 6 and 224 nm at Neumayer III station during...
We measured the aerosol size distribution between 6 and 224 nm with a Scanning Mobility Particle Sizer (SMPS) at Neumayer III station during the year 2018. The SMPS measures the... -
Aerosol size distribution between 90 and 5000 nm at Neumayer III station duri...
We continuously measured aerosol size distributions in the range between 90 nm and 5000 nm in 64 bit resolution with an optical particle sizer (TSI LAS3340). The measurements... -
Aerosol size distribution between 90 and 5000 nm at Neumayer III station duri...
We continuously measured aerosol size distributions in the range between 90 nm and 5000 nm in 64 bit resolution with an optical particle sizer (TSI LAS3340). The measurements... -
Aerosol size distribution between 6 and 224 nm at Neumayer III station during...
We continuously measured aerosol size distributions in the range between 6 nm and 224 nm in 64 bit per decade resolution by means of a Scanning Mobility Particle Sizer (SMPS,... -
Aerosol size distribution between 6 and 224 nm at Neumayer III station during...
We continuously measured aerosol size distributions in the range between 6 nm and 224 nm in 64 bit per decade resolution by means of a Scanning Mobility Particle Sizer (SMPS,... -
Aerosol size distribution between 18 and 820 nm at Neumayer III station durin...
We continuously measured aerosol size distributions in the range between 18 nm and 820 nm in 64 bit per decade resolution by means of a Scanning Mobility Particle Sizer (SMPS,... -
Aerosol size distribution between 90 and 5000 nm at Neumayer III station duri...
We continuously measured aerosol size distributions in the range between 90 nm and 5000 nm in 64 bit resolution with an optical particle sizer (TSI LAS3340). The measurements... -
High resolved snow height measurements at Neumayer Station, Antarctica (2010 ...
At Neumayer-Station in Antarctica snow height is permanently monitored with a laser distance meter. From 2010-01-27 until 2011-10-11 the instrument was installed for test... -
Aerosol size distribution between 16 and 950 nm at Neumayer III station durin...
We measured the aerosol size distribution between 16 and 950 nm with a Scanning Mobility Particle Sizer (SMPS) at Neumayer III station during the year 2017. Supplement to:... -
Aerosol size distribution between 90 and 5000 nm at Neumayer III station duri...
The aerosol size distribution between 90 and 5000 nm was measured by a Laser Aerosol Spectrometer (LAS 3340) at Neumayer III station during the year 2017. Supplement to:... -
High resolved snow height measurements at Neumayer Station, Antarctica, 2023
At Neumayer-Station in Antarctica snow height is permanently monitored with a laser distance meter. The instrument measures continuously since 2013-01-01 and is located in the... -
High resolved snow height measurements at Neumayer Station, Antarctica, 2024
At Neumayer-Station in Antarctica snow height is permanently monitored with a laser distance meter. The instrument measures continuously since 2013-01-01 and is located in the...
