-
Neon processing and analysis data
(1) Computed by comparison to 20Ne signal in air pipettes. 1-sigma uncertainty includes measurement uncertainty of 20Ne signal in this analysis and the reproducibility of the... -
Beryllium blank sensitivity analysis from the detrital river sediment in cent...
Beryllium blank sensitivity analysis showing comparison between using individual batch blanks and average blanks. -
Aluminium-26 and Beryllium-10 derived erosion rate from the detrital river se...
Note: * Where the 26Al/10Be ratio is significantly below 7 (see Table S7), the erosion rates are overestimes.* The CU-016 Be data are only from the duplicate sample. -
Aluminum and beryllium isotope concentrations and ratios from the detrital ri...
= We used only the DUP Be-10 measurement because we re-leached the sample and concluded the first one was not clean enough. -
Aluminum isotope measurements from the detrital river sediment in central Cuba
This dataset has no description
-
Beryllium isotope measurements from the detrital river sediment in central Cuba
Isotopic analysis was conducted at PRIME Laboratory; ratios were normalized against standard 07KNSTD3110 with an assumed ratio of 2850 x 10^-15 (Nishiizumi et al., 2007). -
Blank data for aluminum measurements
This dataset has no description
-
Blank data for beryllium measurements
This dataset has no description
-
Percentage of each basin underlain by different lithologic units of each samp...
This dataset has no description
-
Sample information from each sample from the detrital river sediment in centr...
This dataset has no description
-
Beryllium 10 blanks processed with Dominica river sediment samples collected ...
This dataset has no description
-
Sample locations and upstream basin average parameters for all sampled waters...
This dataset has no description
-
Sample preparation and laboratory measurement values for in-situ meteoric Ber...
Comments:1) July 2017 refers to samples collected before Hurricane Maria and January 2018 refers to samples collected after Hurricane Maria.2) 2017 samples were measured at... -
Sample preparation and laboratory measurement values for fine-grain meteoric ...
Comments:1) “Fine-grain” refers to sediment grain size <63 μm.2) July 2017 refers to samples collected before Hurricane Maria and January 2018 refers to samples collected... -
Sample preparation and laboratory measurement values for coarse-grain meteori...
Comments:1) “Coarse-grain” refers to sediment grain size 250-850 μm.2) July 2017 refers to samples collected before Hurricane Maria and January 2018 refers to samples collected... -
Meteoric Beryllium 10 flux calculated from latitude and mean annual precipita...
Meteoric 10Be Flux was calculated using Graly's (2011) formula: 10Beflux = P*(1.44/(1+EXP((30.7-L)/4.36))+0.63), where P is mean annual precipitation (cm/yr) and L is latitude. -
In situ Be-10, Al-26, and Ne-21 measurements of detrital river sediment in ce...
We measured the concentration of in situ Be-10 and Al-26 in quartz separated from medium (250-850 micron) detrital river sand collected from 22 watersheds in central Cuba.... -
Detrital in situ and meteoric Beryllium 10 measurements from samples taken be...
Tropical islands, including many in island arcs, are susceptible to recurring disturbances from extreme storms. To test whether such storms bias isotopic indicators of long-term... -
Erosion rates from the detrital river sediment in central Cuba
The different erosion rate estimates have two different types of differences. One is that they were calculated using different isotopes in the rocks (26Al and 10Be). These are... -
CRONUS Input of all samples from the detrital river sediment in central Cuba
Input data table for the online calculator described by Balco et al. (2008) (hess.ess.washington.edu) and subsequently updated. Note: This table is set up so that you can open...