Fe(II) kinetic data from from water samples during POSEIDON cruise POS533 (AIMAC)

DOI

At each station, seawater was collected for trace metals sampling at 20 m depth using a Teflon pump (Furon®) with a 40 m Teflon tube connected with a AcroPakTM 1500 capsule w/Supor Memb 0.8/0.2 μm filter. The pump was left to pump to rinse the inner hose and 1 L sample was collected in LDPE bottles (NALGENE) and stored at -20oC until the land-based laboratory analysis. The material was previously cleaned following the trace metals GEOTRACES protocol and the experiments were done in Class 100 clean laboratory or trace metal analysis (QUIMA- IOCAG TM lab).

Identifier
DOI https://doi.org/10.1594/PANGAEA.934051
Related Identifier https://doi.org/10.1021/acs.est.1c04512
Metadata Access https://ws.pangaea.de/oai/provider?verb=GetRecord&metadataPrefix=datacite4&identifier=oai:pangaea.de:doi:10.1594/PANGAEA.934051
Provenance
Creator Santana-Casiano, Juana Magdalena ORCID logo; Quack, Birgit
Publisher PANGAEA
Publication Year 2021
Rights Creative Commons Attribution 4.0 International; https://creativecommons.org/licenses/by/4.0/
OpenAccess true
Representation
Language English
Resource Type Dataset
Format text/tab-separated-values
Size 900 data points
Discipline Earth System Research
Spatial Coverage (-25.000W, 16.900S, -16.900E, 32.630N)
Temporal Coverage Begin 2019-02-28T00:00:00Z
Temporal Coverage End 2019-03-22T00:00:00Z